Complete Measuring Systems FOR COMMERCIAL AND INDUSTRIAL PURPOSES

merni sistemi

Turbines, PTZ

Turbine meter with Maxiflo 9000 flow computer, performs PTZ conversion.

The turbine gauge can optionally be calibrated for high pressure.

Maxiflo 9000 offers:

  • Compensation for measurement error curve
  • Compressibility calculation according to AGA 8, AGA NX 19 or SGERG 88
  • Pressure and temperature transmitters with exceptional accuracy
  • Gas chromatograph connection

Turbines, density

Turbine meter with Maxiflo 9000 flow measurement with density transducer.

The turbine gauge can optionally be calibrated for high pressure.

Maxiflo 9000 offers:

  • Compensation for measurement error curve
  • Flow rate calculation
  • Density transducer, class 0.15% R.
  • PTZ conversion for back-up (optional)
  • Certificates that include the calculation of the accuracy of the entire system

Opening measuring systems

Includes hole filling, simple or advanced (replacement without pressure change)

The Maxiflo 9000 flow computer offers:

  • Flow calculation according to ISO 5167
  • Automatic switching between up to 5 different pressure transmitters

Options:

  • Extremely high precision pressure and differential pressure transmitters
  • Air-conditioned cabin, in order to avoid the influence of temperature on the precision of operating
  • Complete system, including all pipes and fillings
  • Accredited certificates

Distributor:

INTEH D.O.O.
Kneza Višeslava 130, BELGRADE, SERBIA
011 35 53 870
063.223 576
office@inteh.rs